THERMAL SCIENCE
International Scientific Journal
Find this paper on
PREDICTING THE VALUE OF INDOOR CO₂ CONCENTRATION IN A UNIVERSITY AUDITORIUM USING A DECISION TREE ALGORITHM AND A DATA MINING METHOD
ABSTRACT
The aim of this study is to predict the CO2 concentration levels based on data obtained in the auditorium of the new university building of the Faculty of Architecture, Civil Engineering and Geodesy and Faculty of Forestry (FACEG-FF) at the University of Banja Luka in correlation to the operation of the mechanical ventilation system. The data used for the analysis were collected from measurements and surveys on students' subjective perception of indoor thermal and air quality. Data analysis and statistical processing were carried out using Statistical Product and Service Solutions (SPSS). The influence of measured physical parameters and the impact of user behaviour on CO2 concentration using the chi-square automatic interaction detection (CHAID) decision tree technique in a university auditorium was predicted. The dataset comprised 11 input variables (A1-A11), a continuous output variable representing CO₂ concentration (B1, ppm), and two predicted categorical outputs: B2, describing CO₂ concentration classes, and B3, indicating air quality satisfaction based on a 1000 ppm CO₂ threshold. Classification accuracy was between 89.2% and 97.5% for dependent variable B2 (class of indoor air quality) and 94.2% and 99.2% for dependent variable B3 (satisfactory - value below or above 1000 ppm CO₂). The findings indicate that maintaining CO₂ levels below 1000 ppm is crucial for ensuring satisfactory indoor air quality and thermal comfort among occupants.
KEYWORDS
PAPER SUBMITTED: 2026-02-16
PAPER REVISED: 2026-03-19
PAPER ACCEPTED: 2026-03-24
PUBLISHED ONLINE: 2026-05-17
DOI REFERENCE: https://doi.org/10.2298/TSCI260216064P
[1] ***, EU Policy on Air Quality: Implementation of Selected EU Legislation, European Parliamentary Research Service, Brussels, 2021, 10.2861/808342
[2] Lovrić, M., et al., Indoor and Ambient Air Pollution Dataset Using a Multi-Instrument Approach and Total Event Monitoring, Scientific Data, 12 (2025), 1
[3] Al Horr, Y., et al., Impact of Indoor Environmental Quality on Occupant Well-Being and Comfort: A Review of the Literature, International Journal of Sustainable Built Environment, 5 (2016), 1, pp. 1-11
[4] Marques, G., Pitarma, R., Indoor Air Quality Monitoring for Enhanced Healthy Buildings, Indoor Environmental Quality, IntechOpen, London, UK, 2019, 10.5772/intechopen.75787
[5] Corlan, R. V., et al., The Importance of Indoor Air Quality (IAQ) Monitoring, Journal of Physics: Conference Series, 1781 (2021), 1, 012062
[6] Kim, J., et al., Personal Comfort Models: Predicting Individuals' Thermal Preference Using Occupant Heating and Cooling Behavior and Machine Learning, Building and Environment, 129 (2018), pp. 96-106
[7] Hou, F., et al., Prediction and Optimization of Thermal Comfort, IAQ and Energy Consumption of Typical Air-Conditioned Rooms Based on a Hybrid Prediction Model, Building and Environment, 225 (2022), 109576
[8] Jia, L.-R., et al., Interaction between Thermal Comfort, Indoor Air Quality and Ventilation Energy Consumption of Educational Buildings: A Comprehensive Review, Buildings, 11 (2021), 12
[9] Ma, N., et al., Measuring the Right Factors: A Review of Variables and Models for Thermal Comfort and Indoor Air Quality, Renewable and Sustainable Energy Reviews, 2021, 10.1016/j.rser.2020.110436
[10] Bajc, T. S., Indoor Environmental Quality in Non-Residential Buildings - Experimental Investigation, Thermal Science, 20 (2016), 5, pp. 1521-1529
[11] Tomić, M., et al. Measurement and Improvement of Indoor Air Quality in an Information Technology Classroom, Thermal Science, 18 (2014), 3, pp. 915-924
[12] Antunović, B., et al., The First Test of Indoor Air Quality in Kindergartens of the Republic of Srpska, Thermal Science, 28 (2024) 3B, pp. 2565-2578
[13] Lazović, M. I., Impact of CO2 Concentration on Indoor Air Quality and Correlation with Relative Humidity and Indoor Air Temperature in School Buildings, Thermal Science, 20 (2015), 1, pp. 297-307
[14] Lamberti, G., et al., Analysis of the Interplay between Indoor Air Quality and Thermal Comfort in University Classrooms for Enhanced HVAC Control, Energies, 17 (2024), 20
[15] Maiques, M., et al., Energy Implications of Meeting Indoor Air Quality and Thermal Comfort Standards in Mediterranean Schools Using Natural and Mechanical Ventilation Strategies, Energy and Buildings, 2025, 10.1016/j.enbuild.2024.115076
[16] Octaviano, E. C., et al., Numerical Analysis of Air Quality Improvement and Thermal Comfort in a Classroom Using Organic Air Cleaners, Atmosphere, 16 (2025), 6
[17] Mendes, A., et al., Indoor Air Quality and Thermal Comfort - Results of a Pilot Study in Elderly Care Centers in Portugal, Journal of Toxicology and Environmental Health, Part A, 76 (2013), 4-5, pp. 333-344
[18] Andarini, R., Widjaja, M., Monitoring Indoor Air Quality for Thermal Comfort Using Internet of Things, Proceedings of the Seventh International Conference on Informatics and Computing (ICIC), Denpasar, Bali, Indonesia, 2022, pp. 1-6
[19] Allen, J. G., et al., Associations of Cognitive Function Scores with Carbon Dioxide, Ventilation, and Volatile Organic Compound Exposures in Office Workers: A Controlled Exposure Study of Green and Conventional Office Environments, Environmental Health Perspectives, 124 (2016), 6, pp. 805-812
[20] Satish, U., et al., Is CO₂ an Indoor Pollutant? Direct Effects of Low-to-Moderate CO₂ Concentrations on Human Decision-Making Performance, Environmental Health Perspectives, 120 (2012), 12, pp. 1671-1677
[21] Azuma, K., et al., Effects of Low-Level Inhalation Exposure to Carbon Dioxide in Indoor Environments: A Short Review on Human Health and Psychomotor Performance, Environment International, 121 (2018), pp. 51-56
[22] Ren, J., et al., Predicting Education Building Occupants' Thermal Sensation through CatBoost-DF Algorithm, Applied Artificial Intelligence, 37 (2023), 1, 10.1080/08839514.2023.2175115
[23] Čulić, A., et al., Progress in Data-Driven Thermal Comfort Analysis and Modeling, Energy and Buildings, 336 (2025), 115599
[24] Breiman, L., Friedman, J. H., Olshen, R. A., Stone, C. J., Classification and Regression Trees, Wadsworth International Group, Belmont, CA, USA, 1984
[25] Molnar, C., Interpretable Machine Learning: A Guide for Making Black Box Models Explainable, Lulu.com, Morrisville, NC, USA, 2020
[26] Sharma, H., Kumar, S., A Survey on Decision Tree Algorithms of Classification in Data Mining, International Journal of Science and Research, 5 (2016), 4, pp. 2094-2097
[27] Tso, G. K. F., Yau, K. K. W., Predicting Electricity Energy Consumption: A Comparison of Regression Analysis, Decision Tree and Neural Networks, Energy and Buildings, 39 (2007), 11, pp. 1156-1164
[28] Kass, G. V., An Exploratory Technique for Investigating Large Quantities of Categorical Data, Journal of the Royal Statistical Society: Series C (Applied Statistics), 29 (1980), 2, pp. 119-
[29] Agresti, A., An Introduction to Categorical Data Analysis, 3rd ed., John Wiley & Sons, Hoboken, NJ, USA, 2018
[30] Ahmad, M. W., Mourshed, M., Rezgui, Y., Trees vs. Neurons: Comparison between Decision Tree and ANN for High Resolution Prediction of Building Energy Consumption, Building and Environment, 147 (2018), pp. 77-89
[31] Wang, Z., Hong, T., Data-Driven Approach to Estimate the Energy Impact of Occupant Behavior in Buildings, Energy and Buildings, 223 (2020), 110220
[32] Ritschard, G., CHAID and Earlier Supervised Tree Methods, in: Contemporary Issues in Exploratory Data Mining in Behavioral Sciences, Routledge, New York, 2013, pp. 48-74
[33] Ramaswami, M., Bhaskaran, R., A CHAID-Based Performance Prediction Model in Educational Data Mining, IJCSI International Journal of Computer Science Issues, 7 (2010), pp. 1694-0814
[34] Yang, Y., et al., Performance Analysis of the CHAID Algorithm for Accuracy, Mathematics, 11 (2023), 11
[35] Farrahi, V., et al., Correlates of Physical Activity Behavior in Adults: A Data Mining Approach, International Journal of Behavioral Nutrition and Physical Activity, 17 (2020), 1
[36] Navidi, W., Statistics for Engineers and Scientists, 3rd ed., McGraw-Hill, New York, USA
[37] Field, A., Discovering Statistics Using IBM SPSS Statistics, Sage Publications, London, UK
[38] ***, Regulation on Performing Energy Audits and Energy Certification of Buildings, Official Gazette of the Republic of Srpska, No. 30/15, 2015 (in Serbian language)
[39] ***, Ventilation for Acceptable Indoor Air Quality, ANSI/ASHRAE Standard 62.1-2021, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Peachtree Corners, GA, USA
[40] ***, Ergonomics of the Thermal Environment - Analytical Determination and Interpretation of Thermal Comfort Using Calculation of the PMV and PPD Indices and Local Thermal Comfort Criteria, BAS EN ISO 7730:2010, European Committee for Standardization (CEN), Brussels, Belgium
[41] ***, Ergonomics of the Thermal Environment - Instruments for Measuring Physical Quantities, BAS EN ISO 7726:2010, European Committee for Standardization (CEN), Brussels, Belgium
[42] ***, Energy Performance of Buildings - Ventilation for Buildings - Part 1: Indoor Environmental Input Parameters for Design and Assessment of Energy Performance of Buildings, Addressing Indoor Air Quality, Thermal Environment, Lighting and Acoustics-Module M1-6, EN 16798-1:2020, European Committee for Standardization (CEN), Brussels, Belgium
[43] Kotur, M., et al., Analysis of Indoor Air Quality in the Amphitheatre with Mechanical Ventilation of the New Educational Building at the University of Banja Luka, Proceedings of the 20th SDEWES Conference on Sustainable Development of Energy, Water and Environment Systems, Dubrovnik, Croatia
© 2026 Society of Thermal Engineers of Serbia. Published by the Vinča Institute of Nuclear Sciences, National Institute of the Republic of Serbia, Belgrade, Serbia. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International licence


