STUDY ON THE IMPACT OF NEAR-WALL AIR SYSTEMS' WIND SPEED VARIATIONS ON THE COMBUSTION CHARACTERISTICS IN COAL-FIRED BOILERS
ABSTRACT
With increasingly strict national energy policies mandating ultra-low emissions for coal-fired power plants, the issue of high temperature corrosion caused by reductive gases and elevated furnace temperatures has become critical. This study proposes the implementation of near-wall air systems on both sides of mid-furnace burners to mitigate water-cooled wall corrosion and enhance combustion efficiency. Using numerical simulation, the effects of a near-wall air system with a wind speed of 20 m/s were analyzed across the entire furnace. Results show that this approach reduces the average near-wall temperature by 4%, while increasing O₂ concentration in the combustion zone by approximately 6%, thus promoting more efficient combustion. Additionally, CO₂ and CO concentrations decrease by about 4.5% and 5.9%, respectively, effectively reducing reductive gases and alleviating high-temperature corrosion. The NOx decreased significantly by 18.7%, indicating that air classification effectively suppressed NOx, which is a sign of efficient and low-nitrogen combustion. These findings offer a practical solution for improving boiler operational safety and efficiency under ultra-low emission requirements.
KEYWORDS
PAPER SUBMITTED: 2025-11-13
PAPER REVISED: 2026-01-05
PAPER ACCEPTED: 2026-01-29
PUBLISHED ONLINE: 2026-03-07
DOI REFERENCE: https://doi.org/10.2298/TSCI251113021C
CITATION EXPORT: view in browser or download as text file
[1] Wang, J., Research Status and Progress of Natural Gas Low-Nitrogen Combustion Technology, Modern Chemical Industry, 42 (2022), S2, pp. 47-50
[2] Ke,H., et al., Cause Analysis and Preventive Measures for Boiler Water Wall Leakage in 350 MW Unit of a Thermal Power Plant, Die & Mould Manufacture, 25 (2025), 07, pp. 247-249
[3] Juncheng, X., et al., Simulation Research on Thermal Management System of Battery Module with Fin Heat Dissipation Structure, Applied Thermal Engineering, 239 (2024), 122177
[4] Ke, C., Analysis of the Principle of High-Temperature Corrosion of Water-Cooled Walls in Supercritical Boilers and the Problem of Wall-Adhering Air Modification, Science and Technology & Innovation, 12 (2025), 9, pp. 229-232
[5] Tao, Q., Wang, Y., Analysis of Causes and Prevention of High-Temperature Corrosion in the Water-Cooled Walls of a 1000 MW Corner-Tangential Coal-Fired Boiler, Mechanical and Electrical Information, 18 (2023), pp. 62-66
[6] Liu, T., et al., Numerical Investigation of Stable Combustion at Ultra-Low Load for a 350 MW Wall Tangentially Fired Pulverized-Coal Boiler: Effect of Burner Adjustments and Methane Co-Firing, Applied Thermal Engineering, 246 (2024), 122980
[7] Shim, H.-S., et al., Development of Fireside Waterwall Corrosion Correlations Using Pilot-Scale Test Furnace, Fuel, 87 (2008), 15/16, pp. 3353-3361
[8] Xiaohe, X., et al., Water Wall Tubes' High Temperature Corrosion Root Cause Investigation: A 300 MW Level Boiler Case, Energies, 16 (2023), 4, pp. 1767-1767
[9] Bai, F., High Temperature Corrosion Analysis and Treatment Measures of Water Wall of 600 MW Sub-critical Pulverized Coal Boiler, Power System Engineering, 40 (2024), 03, pp. 52-54+57
[10] Zhenhua, Y., et al., An Innovative Low-NOx Combustion Technology for Industrial Pulverized Coal Boiler: Gas-Particle Flow Characteristics with Different Radial-Air-Staged Levels, Energy, 260 (2022), 125142
[11] Wei, J., et al., Numerical Study on the Effects of Primary Air Ratio on Ultra-Low-Load Combustion Characteristics of a 1050 MW Coal-Fired Boiler Considering High-Temperature Corrosion, Applied Thermal Engineering, 221 (2023), 119811
[12] Xu, S., et al., Study on High Temperature Corrosion Mechanism of Water Wall Tubes of 350 MW Supercritical Unit, Engineering Failure Analysis, 121 (2021), 105131
[13] Yunfei, S., et al., Cause Analysis of Corrosion and Burst of Water Wall of Utility Boiler, Journal of Physics: Conference Series, 2399 (2022), 1, 012031
[14] Zixiang, L., et al., A Novel Burner Arrangement Scheme with Annularly Combined Multiple Airflows for Wall-Tangentially Fired Pulverized Coal Boiler, Energy, 222 (2021), 119912
[15] Qiu, Z., Jianxin, Q., Mechanism Analysis for High-Temperature Corrosion Behaviors of Boiler Water-Wall Tube and Its Arc Spraying NiCr Coating in a Power Plant, Thermal Power Generation, 53 (2024.), 07, pp. 143-148
[16] Xie, P., Xu, L., The Analysis on the Causes of the Water Wall Pipe Burst in Industrial Boilers, Journal of Engineering Mechanics and Machinery, 8 (2023), 1, 080102
[17] Yue, J., Huang, J., Analysis and Prevention of High-Temperature Corrosion in the Water-Cooled Walls of a 1000 MW Ultra-Supercritical Double-Opposed-Firing π-Shaped Pulverized Coal Boiler, Energy Research and Utilization, 36 (2024), 03, pp. 35-39
[18] Xue, W., et al., Influences of Operation Parameters on Blended Combustion Zhundong Coal in 330 MW Coal-Fired Boilers, Journal of University of Jinan (Science and Technology), 37 (2023), 03, pp. 380-388
[19] Xiaohe, X., et al., Water Wall Tubes' High Temperature Corrosion Root Cause Investigation: A 300 MW Level Boiler Case, Energies, 16 (2023), 4, pp. 1767-1767
[20] Ma, H., et al., Design of Porous Wall Air Coupling with Air Staged Furnace for Preventing High Temperature Corrosion and Reducing NOx Emissions, Applied Thermal Engineering, 124 (2017), Sept., pp. 865-870
[21] Zhao, L. Z., Ming, F. Y., Numerical Simulation of the Effects of Charge Stratification on Combustion and Emissions, Energy & Fuels, 21 (2007), 4, pp. 2018-2026
[22] Ettouati, H., et al., Numerical Modelling and Simulation of Pulverized Solid-Fuel Combustion in Swirl Burners, The Canadian Journal of Chemical Engineering, 87 (2009), 3, pp. 350-358
[23] Li, D., et al., Numerical Study of Co-Firing Biomass with Lean Coal Under Air-Fuel and Oxy-Fuel Conditions in a Wall-Fired Utility Boiler, Energy & Fuels, 31 (2017), 5, pp. 5344-5354
[24] Yao, L., et al., Influence of Closing-to-Wall Air on Combustion Process in 660 MW Opposed Firing Boiler, Journal of Southeast University(Natural Science Edition), 45 (2015), 01, pp. 85-90
[25] Ma, L., et al., More Efficient and Environmentally Friendly Combustion of Low-Rank Coal in a Down-Fired Boiler by a Simple but Effective Optimization of Staged-Air Windbox, Fuel Processing Technology, 194 (2019), 106118
[26] Wen, H., et al., Numerical Simulation and Practical Verification of Near-Wall Air System for an Ultra-Supercritical Boiler, Electric Power Technology and Env. Protection, 41 (2025), 03, pp. 488-496
[27] Yu, Y., et al.,. Influence of Closing-to-Wall Air on Combustion in 300 MW Firing Boiler, Boiler Manufacturing, 30 (2024), 02, pp. 16-18+21
[28] Chen, Q., et al., Numerical Simulation and Practical Verification of Near-Wall Air System for an Ultra-Supercritical Boiler, Journal of Engineering for Thermal Energy and Power, 37 (2022.), 10, pp. 112-121
[29] Habib, M. A., et al., Computational Fluid Dynamic Simulation of Oxyfuel Combustion in Gas-Fired Water Tube Boilers, Computers and Fluids, 56 (2012), pp. 152-165
[30] Mohamadreza, E., et al., CFD Simulation and Optimization of an Industrial Cement Gas-Solid Air Classifier, Particuology, 89 (2024), June, pp. 172-184
[31] Zixiang, L., et al., Low Load Performance of Tangentially-Fired Boiler with Annularly Combined Multiple Airflows, Energy, 224 (2021), 120131
[32] Weijuan, Y., et al., Effects of Near-Wall Air Application in a Pulverized-Coal 300 MWe Utility Boiler on Combustion and Corrosive Gases, Energy & Fuels, 31 (2017), 9, pp. 10075-10081
[33] Lu, K., et al., Numerical Study on Combustion Characteristics of Wall-Type Tangential Boiler, IOP Conference Series: Earth and Environmental Science, 237 (2019), 2, pp. 022043-022049
[34] Hyunbin, J., et al., Influence of Uneven Secondary Air Supply and Burner Tilt on Flow Pattern, Heat Transfer, and NOx Emissions in a 500 MWe Tangential-Firing Coal Boiler, Energies, 14 (2021), 24, pp. 8352-8352
[35] Hao, L., et al., Numerical Simulation of Combustion Characteristics in a 660 MW Tangentially Fired Pulverized Coal Boiler Subjected to Peak-Load Regulation, Case Studies in Thermal Engineering, 49 (2023), 103168
[36] Yanyu, Q., et al., Combustion and NOx Formation Characteristics from a 330 MWe Retrofitted Anthracite-Fired Utility Boiler with Swirl Burner Under Deeply-Staged-Combustion, Energy, 258 (2022), 124832
[37] Bo, Z., et al., Study on Combustion Characteristics and NOx Formation in 600 MW Coal-Fired Boiler Based on Numerical Simulation, Energies, 16 (2022), 1, pp. 262-262
[38] Dafu, M., et al.,. Combustion Stability and NOx Emission Characteristics of Three Combustion Modes of Pulverized Coal Boilers Under Low or Ultra-Low Loads, Applied Energy, 353 (2024), Part A, 121998
[39] Wang, J., et al., Numerical Simulation of a Decoupling and Reburning Combinative Low-NOx Coal Grate Boiler, Journal of Cleaner Production, 188 (2018), July, pp. 977-988
[40] Xu, S., et al., Simulation Study on Effect of New Combined Closing-to-Wall Air on High Temperature Corrosion Atmosphere of Boiler Water Wall, Thermal Power Generation, 51 (2022), 04, pp. 79-87
[41] Huang, L., et al., Numerical Study on the Effect of the Over-Fire-Air to the Air Flow and Coal Combustion in a 670 t/h Wall-Fired Boiler, Fuel Processing Technology, 87 (2005), 4, pp. 363-371
[42] Zeng, J., High Temperature Corrosion Analysis and Treatment of Water Wall of 350 MW Opposed Firing Boiler, Industrial Boilers, 42 (2022), 01, pp. 51-53+62
[43] Pei, J., et al., Optimizing the Combustion of Low-Quality Coal by the Wall Wind Auxiliary Combustion Method in a Tangentially Fired Utility Boiler, Combustion Science and Technology, 191 (2019), 3, pp. 570-589
[44] Si, W., et al., Combustion Performance and NOx Emissions in a 330 MW Tangentially Fired Boiler Ret-rofitted with Preheating Combustion Devices, Energy, 318 (2025), 134803
[45] Ling, S., et al., Optimization Study of Low-NOx Combustion in Boiler Based on Pulverized Coal Pre-heating Solution, Case Studies in Thermal Engineering, 65 (2025), 105647
© 2026 Society of Thermal Engineers of Serbia. Published by the Vinča Institute of Nuclear Sciences, National Institute of the Republic of Serbia, Belgrade, Serbia. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution 4.0 International licence